containerised Hospital waste incinerator

One 40′ Standard – containerised Incinerator, and understand you can help us with the procurement of the same.Waste type or application  : General and Medicine

Capacity kgs / hour             : 75 to 350
Hospital and Laboratory equipment. .

One of our valued customer is interested to purchase a Hospital Waste incinerator as per following specifications:

Hospital waste incinerator
Capacity: 50 Kg / Hour
Brand new complete working unit
Burners: Dual fired (Gas and diesel)
20ft container with an incinerator plant for burning solid waste including the following main items:

1. INCINERATOR
2. SPARK ARRESTER
3. FLUE GAS STACK / EXHAUST PIPE
4. DIESEL OIL DAYTANK 400 L NET
5. INTEGRATED FIRE FIGHTING SYSTEM
6. INSTRUCTION MANUALS
7. SPARE PARTS FOR 1 YEARS OPERATION
medical waste  incinerator is from 2.5 to 3 cubic meters and it’s capacity is from 60 t0 100kg per hour.

incinerators

small hospital waste incinetor

WASTE INCINERATOR

–          150 KG/HR

–          Compliant with EU rules, Directive 2000/76/EC

–          Fuel type: Diesel

–          Easy management and maintenance

–          Temperatures:

850 deg C for municipal waste

1000 deg C for medical waste

1100 deg C for dangerous waste containing halogenated organic substances with content of chlorine or its compounds.a incinerator with an avarage burning capacity of 20-30kgs per hour and it should diesel or used motor oil,  MEDICAL INCINERATORS, CAP: 3 TONS.producer of small hospital waste incinetor – for our clients (hospitals)

waste disposal incinerator

Incinerator but the size of chamber > 2000 x >1200 mm. Prepare for burn LIQUID Waste +/- 20 liter/hr.
Fueled by Heavy OIL Burner.waste disposal incinerator, capable of handling both wet and dry garbage.. Which include house hold wastes and dry leaves.
The chamber of the incinerator should be able to hold about 200 – 250 kilogram of waste at a given time. edical Waste Incinerators.
The mobile unit is our priority then the fixed units. Medical Waste Incinerators. The mobile unit is our priority then the fixed units.
a;  Batch Capacity for each model, how much load can we put in one time. I need tio under stand in term of batch load one time I can ut in Kgs.
b:  Burning capacity per hour, to know how much time it will take to burn one batch and what is cooling timem for each one.
c: How many batch can we put in each day basis per 24 hours.
d: Most of systems will be run on Gas, so I need to know the required pressure of gas in psi to run the system without any problem.
e; I do wish to know an average life of system and after how many years we need the repair of linning etc.

2. What is your minimum capacity and maximum capacity incinerator.

3. You do provide secodn hand incinerator in good working condition.
4. We need only double chamber double burner incinerator.
5. Please send us DEFRA and DADR approval reports by attachment, copy of ISO and summary of gas emmission report from incinerators.

incinerator for medical waste

factory installed Diesel Fired Incinerator

Estimados, agradecería una cotización por los hornos crematorios para mascotas modelo YD-30 / YD-50.Mobile Diesel Fired  Incinerator model
supplied with the following specifications:
complete with constant ventilation fans for extraction,
factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping.
Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications.
Installed in Container (ISO) : 20”
or its nearest equivalent model plan to build a incinerator plant with 3 units of incinerators at the capacity of 500kg per hour each.
Together with other facilities like operation office, store, space to clean waste containers and 3-4 worker living quarters.
Necesito saber
1.ficha tecnida
2.guía mecanica
3.elevaciones
4. Los quemadores son Ecologicos.??  5.’caracteristicas generales
Del YD 50  and. YD 100  Long Life pet crematory
in Diesel ….Me interesa este producto  Long Life Pet Crematory (YD-50), y quiero conocer más detalles sobre:
Dame la lista de precios exactos por favor.
Me gustaría pedir algunas muestras. ¿Podría  enviarme la lista de precios de muestras?Raw Medical Waste Incinerators. Can you please provide an official cost quote for purchase of (2) incinerators, whichever model has a comparable Capacity = 30 kg/hr.

incinerators

Incinerator capacity of destruction of 350 kg/hour

average daily slaughter is about 120 pigs. The Condemned material and byproducts from the abattoir for disposal is around 1000 kgs.daily
one line incinerator for the destruction of hazardous medical waste.

– Incinerator capacity of destruction of 350 kg/hour, calorific value of waste will be 13-25 MJ/kg

[3,500 kcal/kg] and maximum heat capacity 1,225,000 kcal/hr.

– Incinerator destruction capacity will be 8.4 tons/day and operation time will be 24 hr./day.

– Waste will be through automatic feeding system into the incinerator.

-The temperature will modulated in varying flow and percentage in oxygen, combustion gas is re-burned

in the re-combustion[secondary] chamber at a temperature of minimum 1,100 C during 2 seconds.

– Control panel will be fitted with a functional synoptic view showing the operating situation of the whole

incinerator and controlled by DCS/PLC system.

– Gas treatment system will respect the EE standard [Directive 2000/76/EC-4/12/2000.

– TOC of slag and bottom ashes will be less 3% of the dry weight.

– Installation will be completely free from visible smoke.

– Incinerator will be designed as a Packaged unit, having electrical connection pre-wired and final pipes

in place.

– Incinerator will have automatic de-ashing system with upward direction.

– Incinerator will have flue gas treatment system inclusive [emergency by-pass stack, gas cooling system,

two reactors and particulates filtering system] and guarantee of emissions out of incinerator.

– Training of AKU staffs at site.

– Site may be inspected and examine existing ATI machine, capacity 150 kg/hr.in 24 hour operation.

– Existing infrastructure space is available in basement, 100’ Length  x 30’ wide x 20’ Height for 2nd Incinerator.

– Existing chimney length is 12 meter, and width is 24”dia.

Refractory Concrete Incinerator

2 medical waste incinerators model YD-50, 150 kg feed capacity, 220/380 V, 50 Hz c/w 5 mtr. chimney.
Bio-medical waste management plant requirements:

Disinfecting/sterilizing the contaminated medical wastes, main combustion chamber, post combustion chamber, heat exchanger, ash removal units and flue gas treatment systems, with the following details:

Hourly capacity of the system:           from 250 up to 500 Kgs/ hour

Duration of operation:                        from 14 up to 18 hrs/ day

Fuel type to be used:                         Diesel or alternative

Calorific value of the waste:               3500 up to the maximum limit kcal/ Kg

Minimum operating temperature of primary chamber: 1000 degrees celcius

a smaller  capacity of 150 to 250  kg/feed capacity
will be good for comparison. Our main byproducts are the slaughtered unwanted carcass.

•             Using diesel as fuel

•             Capacity 50kg per hour

•             chambers material: Refractory Concrete

•             Number of chambers: Two

•             Manual feed
solicito un horno crematorio para mascotas, de una capacidad de 80 kl, aprox. solo una unidad, especificaciones tecnicas, totalmente industrial, atte. erika martinez peru